高低壓配電柜應(yīng)該怎么擺放?
發(fā)布時間:2023-12-28 來源:http://www.ywf-lanzhou.com/ 瀏覽量:
1、配電柜的標(biāo)高或筆直度超出答應(yīng)偏差,是由于丈量定位不或者是地上凹凸不平形成的,應(yīng)及時進(jìn)行批改。
1. The elevation or straightness of the distribution cabinet exceeding the allowable deviation is due to poor measurement positioning or uneven ground, and should be corrected in a timely manner.
2、 配電柜在設(shè)備鐵架之前未進(jìn)行調(diào)直找正,或設(shè)備時固定點位置偏移形成的,運用吊線重新找正后再進(jìn)行固定。
2. If the distribution cabinet is not straightened and aligned before the equipment iron frame, or if the fixed point position of the equipment is offset, use a suspension wire to re align and then fix it.
3、配電柜面電具、儀表不牢固、平允或距離不均,壓頭不牢、壓頭傷線芯,多股導(dǎo)線壓頭未裝壓線端子。閘具下方未裝卡片框。不緊的應(yīng)擰緊,距離應(yīng)按要求高速均勻,找平整。傷線芯的部分應(yīng)剪掉重接,多股線應(yīng)裝上壓線端子,卡片框應(yīng)補裝。
3. The electrical appliances and instruments on the distribution cabinet surface are not firm, level or uneven in distance, the pressure head is not firm, the pressure head damages the wire core, and the pressure head of multiple wires is not equipped with pressure wire terminals. There is no card frame installed below the gate. The parts that are not tight should be tightened, and the distance should be high-speed and uniform according to the requirements, and the surface should be leveled. The damaged part of the wire core should be cut off and reconnected, multi stranded wires should be equipped with crimping terminals, and card frames should be repaired.
4、配電柜接地導(dǎo)線截面不夠或維護(hù)地線截面不夠,維護(hù)地線串接,對這些不符合要求的應(yīng)按有關(guān)規(guī)定進(jìn)行糾正。
4. The grounding wire section of the distribution cabinet is insufficient or the maintenance ground wire section is insufficient, and the maintenance ground wire is connected in series. Any non-compliance with these requirements should be corrected according to relevant regulations.
5、配電柜后配線擺放不整齊。應(yīng)按支路綁扎成束,并固定在盤內(nèi)。
5. The wiring behind the distribution cabinet is not neatly arranged. It should be tied into bundles according to the branch and fixed in the tray.
6、配電柜(盤)缺零部件,如合頁、鎖、螺絲等,應(yīng)配齊各種設(shè)備所需零部件。
6. The distribution cabinet (panel) lacks components such as hinges, locks, screws, etc., and should be equipped with all necessary components for the equipment.
7、內(nèi)壁粗糙木箱內(nèi)部應(yīng)修理平整,表里做處理,并應(yīng)考慮措施。
7. The rough inner wall of the wooden box should be repaired and leveled, and the surface and interior should be treated, and measures should be considered.
8、配電柜內(nèi)壁焊點銹蝕,應(yīng)補刷防銹漆。鐵柜不得用電(氣)焊進(jìn)行開孔,應(yīng)采用開孔器進(jìn)行開孔。
8. The welding points on the inner wall of the distribution cabinet are corroded and should be repainted with anti rust paint. The iron cabinet shall not be opened with electric (gas) welding, and a hole opener shall be used for opening.
9、配電柜內(nèi)二層板與進(jìn)、出線配管位置處理不當(dāng),形成配線擺放不整齊,在設(shè)備配電柜時應(yīng)考慮進(jìn)出線配管管口位置應(yīng)設(shè)置在二層板后邊。
9. Improper handling of the position of the second floor board and the inlet and outlet piping inside the distribution cabinet has resulted in uneven wiring arrangement. When installing equipment distribution cabinets, it should be considered that the inlet and outlet piping openings should be placed behind the second floor board.
熱門產(chǎn)品 / HOT PRODUCT
新聞 / NEWS RECOMMENDATIONS